Electrical Engineering · Three Phase Load Balance Check
Compare phase-leg currents from supplied loads and report imbalance percentage. Docs: https://www.brainiac.software/api/electrical-engineering/three-phase-load-balance-check
POST https://www.brainiac.software/api/v1/electrical-engineering/three-phase-load-balance-check
0.03 USDC on Base · payTo 0x6428665E83F503904571104311bB78CBb29b975c
Status: verified · payable
Operator badge: embed this endpoint's live status badge — it reads "Verified Payable" only while the probe record backs it.
Settlement: direct to the seller's payTo — 0% HIVE402 take
Payment routes
{
"asOf": "2026-11-04T21:00:00.000Z",
"loads": [
{
"id": "L2",
"kw": 8,
"name": "Lighting A",
"phase": "A",
"powerFactor": 0.95
},
{
"id": "L3",
"kw": 7,
"name": "Lighting B",
"phase": "B",
"powerFactor": 0.95
},
{
"id": "L4",
"kw": 9,
"name": "Lighting C",
"phase": "C",
"powerFactor": 0.95
}
],
"rules": [
{
"code": "CALLER-IMBALANCE",
"description": "Caller imbalance limit",
"id": "RL-BAL",
"source": "Caller project spec",
"subject": "imbalance",
"threshold": 10,
"unit": "%"
}
],
"system": {
"phases": 3,
"voltageV": 400
}
}{
"apiKeyRequired": false,
"checkedAt": "2026-11-04T21:00:00.000Z",
"codeComplianceClaimed": false,
"findings": [
{
"code": "caller_rule_exceeded",
"detail": "Phase imbalance 12.4999% exceeds caller-supplied threshold 10.",
"kind": "conflict",
"subject": "RL-BAL"
}
],
"imbalancePct": 12.4999,
"imbalancePctSupplied": true,
"limitations": [
"Loads, cables, breakers, transformers, power-factor cases, generators, chargers, and optional rule thresholds are copied only from labeled fields supplied by",
"No paid engineering data provider is used and no API key is required."
],
"maxPhaseA": 23.6842,
"maxPhaseSupplied": true,
"minPhaseA": 18.4211,
"minPhaseSupplied": true,
"paidProviderUsed": false,
"phaseASupplied": true,
"phaseA_A": 21.0526,
"phaseBSupplied": true,
"phaseB_A": 18.4211,
"phaseCSupplied": true,
"phaseC_A": 23.6842,
"standardsInvented": false,
"status": "checked",
"withinCallerThreshold": false,
"withinCallerThresholdSupplied": true
}Script Master Labs LLC · SDVOSB · Kinston, NC · Terms · Refunds · Privacy · Sellers · Contact
SML network: ScriptMasterLabs — the main site · SML Dual Market — the human store: human checkout, card & crypto · VA Ratings — VA disability ratings, free for veterans
Agent intel 
| Trust score | pending / 100 · breakdown |
|---|---|
| Probe uptime (30d) | — over 0 probes · daily |
| Avg 402 latency | — ms |
| Paid calls (30d, on-chain) | 0 calls · 0 buyers |
How to call
POST https://www.brainiac.software/api/v1/electrical-engineering/three-phase-load-balance-check · input in body · spec from live-challenge
Input schema
{
"type": "object",
"properties": {
"text": {
"type": "string"
},
"json": {
"type": "string"
},
"csv": {
"type": "string"
},
"file": {
"type": "object"
},
"loads": {
"type": "array"
},
"cables": {
"type": "array"
},
"breakers": {
"type": "array"
},
"transformers": {
"type": "array"
},
"powerFactorCases": {
"type": "array"
},
"generators": {
"type": "array"
},
"chargers": {
"type": "array"
},
"rules": {
"type": "array"
},
"system": {
"type": "object"
},
"asOf": {
"type": "string"
}
},
"additionalProperties": false
}Output schema
{
"type": "object"
}curl -i -X POST 'https://www.brainiac.software/api/v1/electrical-engineering/three-phase-load-balance-check' \
-H 'content-type: application/json' -d '{"loads":[{"id":"L2","name":"Lighting A","phase":"A","kw":8,"powerFactor":0.95},{"id":"L3","name":"Lighting B","phase":"B","kw":7,"powerFactor":0.95},{"id":"L4","name":"Lighting C","phase":"C","kw":9,"powerFactor":0.95}],"rules":[{"id":"RL-BAL","code":"CALLER-IMBALANCE","description":"Caller imbalance limit","threshold":10,"unit":"%","subject":"imbalance","source":"Caller project spec"}],"system":{"voltageV":400,"phases":3},"asOf":"2026-11-04T21:00:00.000Z"}'
Agents: POST https://hive402.scriptmasterlabs.com/mcp → route_task / proxy_call · SDK /sdk/hive402.mjs