Heat Exchanger Fouling Inference
Return inferred exchanger UA and area-based fouling resistance from supplied measured inlet and outlet temperatures.
POST https://klima.halowerk.com/v1/heat-exchanger-fouling-inference
0.005 USDC on Base · payTo 0x2880EdfFF13100677Bf97A3CBdF3Bc34771C4E5E
Status: verified · payable
Operator badge: embed this endpoint's live status badge — it reads "Verified Payable" only while the probe record backs it.
Settlement: direct to the seller's payTo — 0% HIVE402 take
Payment routes
{
"area": 1,
"clean_ua": 1,
"cold_capacity_rate": 1,
"cold_in": 0,
"cold_out": 25,
"flow": "counter",
"hot_capacity_rate": 1,
"hot_in": 100,
"hot_out": 75
}Script Master Labs LLC · SDVOSB · Kinston, NC · Terms · Refunds · Privacy · Contact
SML network: ScriptMasterLabs — the main site · SML Dual Market — the human storefront · VA Ratings — VA disability ratings, free for veterans
Agent intel 
| Trust score | 73 / 100 · breakdown |
|---|---|
| Probe uptime (30d) | 100.0% over 1 probes · daily |
| Avg 402 latency | 485 ms |
| Paid calls (30d, on-chain) | 978 calls · 7 buyers · shared price cohort of 1537 |
| Facilitator-reported (30d) | 1 calls · 1 payers (CDP Bazaar) |
How to call
POST https://klima.halowerk.com/v1/heat-exchanger-fouling-inference · input in body · spec from live-challenge
Input schema
{
"type": "object",
"properties": {
"hot_capacity_rate": {
"type": "number",
"minimum": 0.000001,
"maximum": 1000000000
},
"cold_capacity_rate": {
"type": "number",
"minimum": 0.000001,
"maximum": 1000000000
},
"hot_in": {
"type": "number",
"minimum": -1e+30,
"maximum": 1e+30
},
"hot_out": {
"type": "number",
"minimum": -1e+30,
"maximum": 1e+30
},
"cold_in": {
"type": "number",
"minimum": -1e+30,
"maximum": 1e+30
},
"cold_out": {
"type": "number",
"minimum": -1e+30,
"maximum": 1e+30
},
"clean_ua": {
"type": "number",
"minimum": 0.000001,
"maximum": 1000000000
},
"area": {
"type": "number",
"minimum": 0.000001,
"maximum": 1000000000
},
"flow": {
"enum": [
"counter",
"parallel"
]
}
},
"required": [
"hot_capacity_rate",
"cold_capacity_rate",
"hot_in",
"hot_out",
"cold_in",
"cold_out",
"clean_ua",
"area",
"flow"
],
"additionalProperties": false
}curl -i -X POST 'https://klima.halowerk.com/v1/heat-exchanger-fouling-inference' \
-H 'content-type: application/json' -d '{"hot_capacity_rate":1,"cold_capacity_rate":1,"hot_in":100,"hot_out":75,"cold_in":0,"cold_out":25,"clean_ua":1,"area":1,"flow":"counter"}'
Agents: POST https://hive402.scriptmasterlabs.com/mcp → route_task / proxy_call · SDK /sdk/hive402.mjs