Solar Design · Nec 690 Current
Compute PV circuit maximum current and minimum conductor ampacity using NEC 690.8 125% factors for the selected code edition. Docs: https://www.brainiac.software/api/solar-design/nec-690-current
POST https://www.brainiac.software/api/v1/solar-design/nec-690-current
0.02 USDC on Base · payTo 0x6428665E83F503904571104311bB78CBb29b975c
Status: verified · payable
Operator badge: embed this endpoint's live status badge — it reads "Verified Payable" only while the probe record backs it.
Settlement: direct to the seller's payTo — 0% HIVE402 take
Payment routes
{
"continuousFactor": 1.25,
"edition": "2023",
"moduleIsc": 14,
"parallelStrings": 2
}{
"edition": "2023",
"limitations": [
"Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code compliance determinations, or utility",
"Applies NEC 690.8(A)(1)(a)(1) and 690.8(B) 125% factors only; 2023 alternative methods are out of scope."
],
"maxCircuitCurrent": 35,
"minConductorAmpacity": 43.75,
"minOcpdRating": 43.75,
"perStringMaxCurrent": 17.5,
"sources": [
{
"retrievedAt": "2026-11-14",
"source": "Caller-supplied module, inverter, irradiance and site inputs processed locally",
"status": "ok",
"url": "https://www.brainiac.software/api/v1/solar-design"
},
{
"retrievedAt": "2026-11-14",
"source": "NFPA 70 National Electrical Code §690.8 factors (2017/2020/2023 editions); formula cited only, NFPA text not vendored",
"status": "ok",
"url": "https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70"
}
]
}Script Master Labs LLC · SDVOSB · Kinston, NC · Terms · Refunds · Privacy · Sellers · Contact
SML network: ScriptMasterLabs — the main site · SML Dual Market — the human store: human checkout, card & crypto · VA Ratings — VA disability ratings, free for veterans
Agent intel 
| Trust score | pending / 100 · breakdown |
|---|---|
| Probe uptime (30d) | — over 0 probes · daily |
| Avg 402 latency | — ms |
| Paid calls (30d, on-chain) | 0 calls · 0 buyers |
How to call
POST https://www.brainiac.software/api/v1/solar-design/nec-690-current · input in body · spec from live-challenge
Input schema
{
"type": "object",
"properties": {
"edition": {
"type": "string",
"enum": [
"2017",
"2020",
"2023"
],
"description": "edition supplied by the caller for this operation.",
"example": "2023"
},
"moduleIsc": {
"type": "number",
"description": "module Isc supplied by the caller for this operation.",
"example": 14
},
"parallelStrings": {
"type": "integer",
"maximum": 9007199254740991,
"description": "parallel Strings supplied by the caller for this operation.",
"example": 2
},
"continuousFactor": {
"type": "number",
"description": "continuous Factor supplied by the caller for this operation.",
"example": 1.25
}
},
"required": [
"moduleIsc"
],
"additionalProperties": false
}Output schema
{
"type": "object",
"additionalProperties": true,
"properties": {
"maxCircuitCurrent": {
"type": "integer",
"description": "max Circuit Current returned by this operation."
},
"minConductorAmpacity": {
"type": "number",
"description": "min Conductor Ampacity returned by this operation."
},
"minOcpdRating": {
"type": "number",
"description": "min Ocpd Rating returned by this operation."
},
"perStringMaxCurrent": {
"type": "number",
"description": "per String Max Current returned by this operation."
},
"edition": {
"type": "string",
"description": "edition returned by this operation."
},
"sources": {
"type": "array",
"description": "Provenance only — upstream name, url, and retrievedAt when available.",
"items": {
"type": "object",
"additionalProperties": true,
"properties": {
"source": {
"type": "string",
"description": "Named upstream source for this delayed reference series."
},
"url": {
"type": "string",
"description": "Requested public URL."
},
"retrievedAt": {
"type": "string",
"description": "ISO-8601 timestamp when upstream data was retrieved."
},
"status": {
"type": "string",
"description": "Coverage status: complete or partial with real data is charged on HTTP 2xx; failed or empty payloads return non-2xx and are not charged."
}
}
}
},
"limitations": {
"type": "array",
"description": "Product caveats. Absence of a signal is not a safety approval."
}
}
}curl -i -X POST 'https://www.brainiac.software/api/v1/solar-design/nec-690-current' \
-H 'content-type: application/json' -d '{"edition":"2023","moduleIsc":14,"parallelStrings":2,"continuousFactor":1.25}'
Agents: POST https://hive402.scriptmasterlabs.com/mcp → route_task / proxy_call · SDK /sdk/hive402.mjs