Solar Design · Dc Ac Ratio Check
Compute the DC/AC ratio and optionally estimate AC energy and clipping from a caller DC power series with constant efficiency or a PVWatts inverter curve. Docs: https://www.brainiac.software/api/solar-design/dc-ac-ratio-check
POST https://www.brainiac.software/api/v1/solar-design/dc-ac-ratio-check
0.03 USDC on Base · payTo 0x6428665E83F503904571104311bB78CBb29b975c
Status: verified · payable
Operator badge: embed this endpoint's live status badge — it reads "Verified Payable" only while the probe record backs it.
Settlement: direct to the seller's payTo — 0% HIVE402 take
Payment routes
{
"acRatingKw": 25,
"dcNameplateKw": 29.7,
"dcPowerSeriesKw": [
0,
2,
8,
15,
22,
27,
29,
27,
22,
15,
8,
2,
0
],
"intervalHours": 1,
"inverterEfficiency": 0.96,
"ratioWarnAbove": 1.3
}{
"acEnergyKwh": 165.24,
"clippedEnergyKwh": 4.679999999999996,
"clippingFraction": 0.02754237288135591,
"dcAcRatio": 1.188,
"limitations": [
"Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code compliance determinations, or utility",
"Without dcPowerSeriesKw only the nameplate DC/AC ratio is returned."
],
"sources": [
{
"retrievedAt": "2026-11-14",
"source": "Caller-supplied module, inverter, irradiance and site inputs processed locally",
"status": "ok",
"url": "https://www.brainiac.software/api/v1/solar-design"
},
{
"retrievedAt": "2026-11-14",
"source": "PVWatts Version 5 Manual (Dobos 2014, NREL/TP-6A20-62641)",
"status": "ok",
"url": "https://www.nrel.gov/docs/fy14osti/62641.pdf"
}
],
"warnings": []
}Script Master Labs LLC · SDVOSB · Kinston, NC · Terms · Refunds · Privacy · Sellers · Contact
SML network: ScriptMasterLabs — the main site · SML Dual Market — the human store: human checkout, card & crypto · VA Ratings — VA disability ratings, free for veterans
Agent intel 
| Trust score | pending / 100 · breakdown |
|---|---|
| Probe uptime (30d) | — over 0 probes · daily |
| Avg 402 latency | — ms |
| Paid calls (30d, on-chain) | 0 calls · 0 buyers |
How to call
POST https://www.brainiac.software/api/v1/solar-design/dc-ac-ratio-check · input in body · spec from live-challenge
Input schema
{
"type": "object",
"properties": {
"dcNameplateKw": {
"type": "number",
"description": "dc Nameplate Kw supplied by the caller for this operation.",
"example": 29.7
},
"acRatingKw": {
"type": "number",
"description": "ac Rating Kw supplied by the caller for this operation.",
"example": 25
},
"inverterEfficiency": {
"type": "number",
"maximum": 1,
"description": "inverter Efficiency supplied by the caller for this operation.",
"example": 0.96
},
"dcPowerSeriesKw": {
"type": "array",
"items": {
"type": "number",
"minimum": 0
},
"description": "dc Power Series Kw supplied by the caller for this operation.",
"example": [
0,
2,
8,
15,
22,
27,
29,
27,
22,
15,
8,
2,
0
]
},
"intervalHours": {
"type": "number",
"description": "interval Hours supplied by the caller for this operation.",
"example": 1
},
"ratioWarnAbove": {
"type": "number",
"description": "ratio Warn Above supplied by the caller for this operation.",
"example": 1.3
},
"useCecCurve": {
"type": "boolean",
"description": "use Cec Curve supplied by the caller for this operation."
}
},
"required": [
"dcNameplateKw",
"acRatingKw"
],
"additionalProperties": false
}Output schema
{
"type": "object"
}curl -i -X POST 'https://www.brainiac.software/api/v1/solar-design/dc-ac-ratio-check' \
-H 'content-type: application/json' -d '{"dcNameplateKw":29.7,"acRatingKw":25,"inverterEfficiency":0.96,"dcPowerSeriesKw":[0,2,8,15,22,27,29,27,22,15,8,2,0],"intervalHours":1,"ratioWarnAbove":1.3}'
Agents: POST https://hive402.scriptmasterlabs.com/mcp → route_task / proxy_call · SDK /sdk/hive402.mjs